Gongyi Xinqi Polymer Co., Ltd.NONIONIC POLYACRYLAMIDE
Product & application catalogue

NPAM / TECHNICAL NOTE

Nonionic Polyacrylamide for Coal Washing: Supplier Trial Requirements

Ask for a coal-fines comparison tied to the circuit, not a generic mining-polymer guarantee.

Illustrative mineral-process water separation installation
Illustrative process scene; illustration, not a photograph of a certified product.

Describe the duty before requesting a grade

Identify whether the polymer serves clarification, thickening or a downstream filtration step. Record coal-fines origin, changes in the mineral fraction and the presence of upstream reagents. These observations explain why samples from different shifts may respond differently.

Give the supplier the current product, dose basis and actual limitation. A nonionic candidate may merit screening, but the coal-washing label alone does not establish ionic character, molecular profile or a reliable operating dose.

Protect the baseline

Compare candidate and incumbent on material collected for the same test event. Keep mixing and observations consistent and record preparation instructions for each code. If the current product has no documented active fraction, compare commercial consumption explicitly.

Include liquid quality, solids capture and the relevant bed or cake behavior. A visual floc observation should not displace the endpoint needed by the installed equipment. Use the controlled trial plan to retain the comparison conditions.

Check transfer and recycle conditions

Follow the treated material through pumps and the actual route to the separator. If the result deteriorates, compare before-and-after samples rather than assuming the laboratory grade is wrong. The floc-transfer investigation separates preparation, delivery and transfer questions.

Recycle-water conditions may also change across the circuit. Identify stock-preparation water independently from the suspension so the supplier can review both rather than treating a single water analysis as complete.

Qualify the commercial proposal

Request the selected production code, release specification, packaging and documents for the actual order. Preserve the trial sample and retain the conditions that justified advancing it. Confirm the expected consumption and receiving destination rather than assuming sample dispatch implies bulk availability.

For a first order, agree a bounded equipment verification and how a poor result will be investigated. Do not approve an untested substitute simply because its sheet carries the same nonionic description.

Decision record for the quotation

Nonionic Polyacrylamide for Coal Washing: Supplier Trial Requirements — evidence to retain
DecisionEvidence needed
DutyClarification, thickening or filtration requirement is stated separately.
BaselineMatched feed and dose basis connect incumbent and candidate results.
Supply evidenceProduction code and first-order verification are linked to the tested sample.
WhatsAppEmail